Ranges 30" Hg vacuum to 0-6000 psi Overpressure 2X Full Scale (Max. 10,000 psi) Accuracy 1.0% of calibrated span including linearity, hysteresis and temperature effects Input 28 VDC with reverse polarity protection Output 4-20 mADC Adjustable Zero & Span Pots accessible by opening body Compensated Temperature Range 0°C to 65°C (32°F to 149°F) Repeatability Within 0.5% of span Shock Test In accordance with Grade A, Class 1, Type C of MIL-S-901 EMI MIL-STD-461 - In accordance with MIL-P-24212 Process Connection Conforms to MS16142 Electrical Connection MS3102 R14S-5P Standard Others optional Applications Steam, oil, sea water, flue gas, ammonia, oxygen, other gases, fresh water, condensate Approvals QPL approved to MIL-P-24212C |