Ranges
30" Hg vacuum to 0-6000 psi

Overpressure
2X Full Scale (Max. 10,000 psi)

Accuracy
1.0% of calibrated span including linearity, hysteresis and temperature effects

Input
28 VDC with reverse polarity protection

Output
4-20 mADC

Adjustable
Zero & Span Pots accessible by opening body

Compensated Temperature Range
0°C to 65°C (32°F to 149°F)

Repeatability
Within 0.5% of span

Shock Test
In accordance with Grade A, Class 1, Type C of MIL-S-901

EMI
MIL-STD-461 - In accordance with MIL-P-24212

Process Connection
Conforms to MS16142

Electrical Connection
MS3102 R14S-5P Standard
Others optional

Applications
Steam, oil, sea water, flue gas, ammonia, oxygen, other gases, fresh water, condensate

Approvals
QPL approved to MIL-P-24212C